Documentation Center

Launching Two IETPs Simultaneously

In order to launch two IETPs on different ports simultaneously, AutoStartID, ProgramTitle, UniqueCDIdentitfier, and port number must be unique.

Procedure

  1. Clear out old configuration. Remove:

    C:\XyEnterprise\ContentaView\var\IETMNAME1

    C:\XyEnterprise\ContentaView\var\IETMNAME2

  2. Update launch.ini, wietmsd.xml, and wietmsd_prg.xml located in

    IETMNAME1\data

    and

    IETMNAME2\data

    respectively, using the configuration below.

  3. Run autoplay.exe to run images of both CDs with new configuration.

Results

Configuration to run multiple instances:

  • launch.ini

    Instance #1:

    AutoStartId=2085
    ProgramTitle=LiveContent Server1
    AccessURL1= http://localhost:2245/servlets3/wietmsd
    AccessURL2= http://localhost:2245/wietmsd3/help/about.html

    Instance #2:

    AutoStartId=2086
    ProgramTitle=LiveContent Server2
    AccessURL1= http://localhost:2246/servlets3/wietmsd
    AccessURL2= http://localhost:2246/wietmsd3/help/about.html
  • wietmsd.xml

    Instance #1:

    <configitem name="UniqueCDIdentifier">
    <value>ITEMNAME1</value>
    </configitem>
    

    Instance #2:

    <configitem name="UniqueCDIdentifier">
    <value>IETMNAME2</value>
    </configitem>
    
  • wietmsd_prg.xml

    Instance #1:

    <configitem name="app.port">
    <comments>Server port</comments>
    <value>2245</value>
    </configitem>
    

    Instance #2:

    <configitem name="app.port">
    <comments>Server port</comments>
    <value>2246</value>
    </configitem>